| Q-1500 |
|
| Output |
| Capacity (VA) |
1500 |
| Capacity (Watts) |
1050 |
| Current (peak amp) 120/230 VAC |
13.7 / 6.4 |
| Waveform |
High resolution, pure sine wave |
| Outlets |
3 |
| Input |
| Current (max amp) 120/230 VAC |
18 / 8 |
| Power factor |
> .95 |
| Frequency |
50/60 Hz (auto) / 45/65 Hz (inverter phase lock range) |
| General |
| UPQ power conditioning topology |
Five (5) Stages of Isolation & Conversion / high frequency, true on-line digital sine wave |
| Desktop Configuration |
Yes |
| Rack Mount Configuration |
Yes |
| Voltage Regulation |
| Input voltage range: |
|
| Full load without using battery |
North America 80 to 140 VAC International 165 to 270 VAC |
| Half load without using battery |
North America 75 to 140 VAC International 160 to 270 VAC |
| Output voltage regulation |
± 2% |
| Isolation |
| Common-mode noise rejection |
Yes |
| Normal-mode noise rejection |
Yes |
| Suppression |
| IEEE 587/ANSI 62.41 3KA/6KV |
170 V normal mode (L or N) / 230 V common mode (L+N to G) |
| surge let-through (NA) |
|
| IEEE 587/ANSI 62.41 3KA/6KV |
340 V normal mode (L or N) / 450 V common mode (L+N to G) |
| surge let-through (international) |
|
| Joules (energy absorption) |
300 |
| Peak surge current (amp) |
80,000 Amps |
| Multi-stage protection |
Yes |
| Normal & common mode certified |
Yes |
| Conditioning |
Yes |
| Output total harmonic distortion |
Less than 3% under linear load, less than 5% under non-linear load |
| Output frequency regulation |
50/60 Hz ± 0.1 Hz (except the synchronization to line during brownout) |
| Input frequency range |
45-65 Hz |
| High Frequency On-Line Inverter |
| Inverter driver frequency |
50 KHz |
| Overload capacity |
>110% continuous |
| Crest factor |
3:1 |
| Transfer time |
Zero |
| Efficiency |
85% |
| UPQ to bypass/bypass to UPQ |
Zero cross transfer, less than 4 ms (2 ms minimum) |
| Battery |
| Full load run time |
> 5 min |
| Half load run time |
> 15 min |
| DC voltage |
36 VDC |
| Recharge time |
5 to 8 hrs |
| Recharge current (amps) |
1.5 |
| Hot-swappable |
No |
| Front panel removal |
No |
| Power Connector |
| Input of 120 V units |
IEC |
| Input of 230 V units |
IEC |
| Output of 120 V units |
(3x) Nema |
| Output of 230 V units |
(3x) IEC |
| Output of 230 V units (Option) |
(1x) L5-20 |
| Nema with Branch Bank Protection |
Yes |
| IEC with Branch Bank Protection |
Yes |
| L5 with Branch Bank Protection |
No |
| Physical |
| WxDxH |
5.5 x 17.3 x 7.5 in (14 x 44 x 19 cm) |
| Weight in lbs/kg |
33 / 15 |
| Battery Charger |
| Microprocessor controller |
Yes |
| Expansion |
No |
| Extended pack option |
No |
| Connect/disconnect |
No |
| Front Panel Display |
| System status information |
Yes |
| Inverter status |
Yes |
| Bypass status |
Yes |
| Load status |
5 segment |
| Battery status |
5 segment |
| Diagnostic status |
Yes |
| Diagnostics |
| POST |
Yes |
| Bypass |
Yes |
| Line to output sync |
Yes |
| Battery status |
Yes |
| Inverter error |
Yes |
| AC input failure |
Yes |
| Overload |
Yes |
| Monitoring |
| Remote shutdown |
Yes |
| Remote diagnostics |
Yes |
| Scheduled shutdown |
Yes |
| Input voltage |
Yes |
| Input frequency |
Yes |
| Output voltage |
Yes |
| Output frequency |
Yes |
| Output load |
Yes |
| Reporting |
Yes |
| Graphing |
Yes |
| Plotting |
Yes |
| Auto Restart (Input Voltage) |
| 110/120 VAC |
>90 - 120 VAC |
| 230 VAC |
>100 - 200 VAC |
| DC Startup |
Yes |
| Environment |
| Audible noise |
< 50 dBA at one meter |
| Temperature |
0 to 40 degrees C |
| Relative humidity |
0 to 95% non-condensing |
| Approvals |
| UL |
Compliant |
| UL medical |
Compliant |
| TUV |
Compliant |
| CE and CE medical |
Yes |
| Warranty |
1 year parts and labor |
| Protection |
| Overload |
> 100% full load / 15-20 sec delay |
| Over/under voltage at I/P, O/P |
Inverter shutdown protection |
| Short circuit |
Yes |
| Over temperature |
Yes |