Rugged UPQ™
Q-RX™ Series Rugged


 
Q-RX™ Products

Q-RX 500
(500 VA / 350 Watts)
Q-RX 700
(700 VA / 490 Watts)
Q-RX 1000
(1000 VA / 700 Watts)
Q-RX 1500
(1500 VA / 1050 Watts)
Q-RX 2000
(2000 VA / 1400 Watts)
Q-RX 3000
(3000 VA / 2000 Watts)


Series Description

The Q-RX Series was designed to meet the most extreme shock, vibration, temperature, and humidity standards. Clean, consistent power for rugged environments is essential to mission-critical electronics. From the demands of moving vehicles to stationary settings with large vibration issues or extended environmental requirements, the Q-RX Series of ruggedized power conditioning and backup provides clean, consistent, and reliable power.

 
Series Features
  • Passes military standards for temperature, humidity, vibration and shock (MIL-STD 167, 810, 810E)
  • Input/Output isolation
  • Clean power output (50kHz switching)
  • High efficiency (longer backup time)
  • Low heat dissipation (cooler operation)
  • AC input and AC output protection
  • Bypass SFT (System Fault Tolerance)
  • Advanced shutdown and monitoring capabilities for single or multiple systems
  • CE Approved
  • Output bank power indicators
  • Independent bank output fusing
  • Hot-swappable batteries
  • Modular battery design  - expandable to your backup needs
  • Multiple charger capability for reduced charging time
  • System air filtering
  • RETMA / Accuride side rail compatible
  • UPQsoft included (see UPQsoft)

 

Options to be purchased with this series:

 
Series Comparison

  Q-RFL 700 Q-RFL 1000 Q-RFL 1500 Q-RFL 2000 Q-RFL 3000
Output
Capacity (VA)

700

1000

1500

2000

3000

Capacity (Watts)

490

700

1050

1400

2000

Current (peak amp) 120/230 VAC

6.4 / 3

9.1 / 4.3

13.7 / 6.4

18.2 / 8.7

27.3 / 13

Waveform High resolution, pure sine wave

Outlets 

6

6

6

4

4

Input
Current (max amp) 120/230 VAC

8 / 4

12 / 5

18 / 8

20 / 10

30 / 16

Power factor

> .95

> .95

> .95

> .95

> .95

Frequency 50/60 Hz (auto) / 45/65 Hz (inverter phase lock range)
General
UPQ power conditioning topology Dual Stage Isolation / High Frequency, True On-line Digital Sine wave
Desktop Configuration Yes
Rack Mount Configuration Yes
Voltage Regulation
Input voltage range:
Full load without using battery North America 80 to 140 VAC International 165 to 270 VAC
Half load without using battery North America 75 to 140 VAC International 160 to 270 VAC
Output voltage regulation ± 2%
Isolation
Common-mode noise rejection Yes
Normal-mode noise rejection Yes
Suppression
IEEE 587/ANSI 62.41 3KA/6KV  170 V normal mode (L or N) / 230 V common mode (L+N to G)
surge let-through (NA)  
IEEE 587/ANSI 62.41 3KA/6KV  340 V normal mode (L or N) / 450 V common mode (L+N to G)
surge let-through (international)  
Joules (energy absorption) 300 Joules
Peak surge current (amp) 80,000 Amps
Multi-stage protection Yes
Normal & common mode certified Yes
Conditioning Yes
Output total harmonic distortion Less than 3% under linear load, less than 5% under non-linear load
Output frequency regulation 50/60 Hz ± 0.1 Hz (except the synchronization to line during brownout)
Input frequency range 45-65 Hz
High Frequency On-Line Inverter
Inverter driver frequency 50 KHz
Overload capacity >110% continuous
Crest factor 3:1
Transfer time Zero
Efficiency 85% Min
UPQ to bypass/bypass to UPQ Zero cross transfer, less than 4 mSec. (2 mSec. minimum)
Battery
Full load run time > 5 min
Half load run time > 15 min
DC voltage

24 VDC

36 VDC

36 VDC

72 VDC

96 VDC

Recharge time

5 to 8 hrs

5 to 8 hrs

5 to 8 hrs

5 to 8 hrs

5 to 8 hrs

Recharge current (amps) 1.5 Amps
Hot-swappable Yes
Front panel removal Yes
Power Connector
Input of 120 V units IEC
Input of 230 V units IEC
Output of 120 V units (4x) Nema
Output of 230 V units  (4x) IEC
Output of 230 V units (Option) (4x) Nema
Nema with Branch Bank Protection Yes
IEC with Branch Bank Protection Yes
L5 with Branch Bank Protection No
L6 with Branch Bank Protection No
Physical
WxDxH

19 x 17.5 x 3.5 (48 x 44.5 x 9 cm)

Weight in lbs/kg

40/18

40 / 18.1

46 / 21

33 / 15

79 / 36

Battery Pack in lbs/kg (optional)

30 / 13.6

35 / 15.9

40/18

50 / 22.7

60 / 27.2

Battery Charger
Microprocessor controller Yes
Expansion Yes
Extended pack option Yes
Connect/disconnect Yes
Front Panel Display
System status information Yes
Inverter status Yes
Bypass status Yes
Load status 4 segment
Battery status 4 segment
Diagnostic status Yes
Diagnostics
POST Yes
Bypass   Yes
Line to output sync Yes
Battery status Yes
Inverter error Yes
AC input failure Yes
Overload   Yes
Monitoring
Remote shutdown Yes
Remote diagnostics Yes
Scheduled shutdown Yes
Input voltage   Yes
Input frequency   Yes
Output voltage   Yes
Output frequency   Yes
Output load Yes
Reporting Yes
Graphing Yes
Plotting Yes
Auto Restart (Input Voltage)
110/120 VAC > 90 - 130 VAC
230 VAC >80 - 260 VAC
DC Startup Yes
Environment
Audible noise < 50 dBA at 1 meter
Temperature (MIL-STD-810) -22° to 140° F (-30° to 60° C)
Relative humidity (MIL-STD-810) 0 to 95% non-condensing
Vibration (MIL-STD-167) 4-50 Hz / 2 g
Shock (MIL-STD-810E) 2 g to 30 g
Approvals
UL Compliant
UL medical Compliant
TUV Compliant
CE and CE medical Yes
Warranty 1 year parts and labor
Protection
Overload > 100% full load / 15-20 sec delay
Over/under voltage at I/P, O/P Inverter shutdown protection
Short circuit Yes
Over temperature Yes

 